Inspect wall/roof intersections for flashing. Flashing should extend at least 4" up the wall and under shingles. EIFS should terminate at least 2" above roof The edges of the insulation board must be wrapped with the base coat, reinforcing mesh, and finish. Caulking should be applied where EIFS and flashing intersect. Inspect for kick outs, turn outs or a diverter to divert water from behind wall where roofs intersect with walls below. Inspect chimneys for flashing, crickets (if necessary) and kick outs, turn outs or a mechanism to divert water from behind walls where roofs intersect with walls below. The interface of the kick out and the EIFS must be caulked. Check for caulking around windows and doors. There should be a 3/8" to 1/2" joint with backer rod and caulking. The edges of the insulation board must be wrapped with the base coat, reinforcing mesh, and finish as required by EIFS manufacturer. Inspect caulking to ensure that it is tightly bonded to each side of the joint. Inspect caulking to ensure its continuity. Inspect penetrations of utility lines and pipes to make sure they are caulked. There should be a 3/8" to 1/2" joint with backer rod and caulking. Inspect penetrations by dryer vents, etc. to make sure they are caulked. There should be a 3/8" to 1/2" joint with backer rod and caulking. Inspect electrical meters and boxes to ensure that the fastener penetrations are sealed. Inspect electrical outlets and light fixtures. These locations should be caulked. Inspect downspout and shutter fastener penetrations to ensure that they are sealed. Inspect locations where decks are attached for effective flashing and waterproofing. Inspect the bottom of walls at decks, patios and entrances for proper termination of the EIFS. The edges of the insulation board must be wrapped with the base coat, reinforcing mesh and finish. There should be a 3/4" joint with backer rod and caulking at these locations. Inspect the bottom of walls at grade to ensure that the insulation board is wrapped with the base coat, reinforcing mesh and finish. If you retain an inspector to inspect your house check their credentials to make sure they have enough expertise to perform a thorough inspection.
Copyright © 1998, J. Dick Hopkins & Associates, Inc. J. Dick Hopkins & Associates, Inc. Wall & Ceiling Consultants Specializing in Exterior Insulation and Finish Systems P.O. Box 81145 Conyers, GA 30013 Telephone 770.760.1177 Facsimile 770.760.0514